Turbine Flowmeter
The Insertion Series Turbine Flowmeter is suitable for liquids or gases. It is designed for retractable operation to meet varying depth applications. The unit can be manufactured with a stem length of 12-36 in. to allow for installation in pipelines from 3-60 in. The insertion meter comes standard with a 2 in. FNPT fitting for attaching to a pipeline. An alignment handle is provided to assist in the insertion and retraction operation permitting proper alignment during installation. Features include portablility, attitude insensitive, custom and standard design, maintenance and installation or removal without line shutdown. Specifications for liquids are as follows: velocity measurement from 2-40 ft/sec and 1% linearity. Specification for gases are: velocity measurement from 20-200 ft/sec and 2% linearity. Repeatability is +/-.25% over nominal rated flow range for liquid or gas.
Sponsler Co., 2363 Sandifer Blvd., Westminster, SC 29693. Phone: 800-258-1165; Fax: 864-647-1255.