On-Line Inspector 5000
Source: RJS Systems International
ANSI reference decode calculation pass/fail
General Specifications, Model OLI 5000
Analysis
Analysis
- ANSI parameters:
ANSI decodability grade calculation A, B, C, D, F
ANSI reference decode calculation pass/fail
- Traditional parameters:
Ratio, Encodation Check, Mod Check, Average Bar Width Deviation, Quiet Zone. Addendum Parity (UPC/EAN)
- Character validation
Symbologies
- Code 39
- Codabar
- Interleaved 2 of 5
- UPC/EAN including 2 and 5 digit addendums
- Code 128
- Code 93
Features
- 5 user programmable outputs
- Bi-directional serial port
- Download language for system interface (some models)
- Choice of synchronization input type
- Free-scan mode
- Programmable communications buffers
- Record keeping
- Multiple bar code analysis
- Programmable synchronization and output polarities
- Data match feature
- Auto discrimination between symbologies or programmable symbology choices
- Verifier stand
User Interface
- 4 button inputs
- System setup via menu
Display
- 2 line x 16 character LCD
- 5 LEDS indicating output status
- LED indicating synchronization status when applicable
Options
- Printer interface kits
Interface
- Two cable interface system
Physical
- Height: 7.5" (191mm)
- Width: 4.25" (108mm)
- Depth: 3.75" (95mm)
- Weight: 2.2 lbs (1 kg)
Power Requirements
- Powered by printer
Scanner
- Moving beam laser scanner
- Visible laser diode light source
- 670 nm (red) wavelength
Regulatory Compliance
- Emission Standards: FCC Class A, CE Class A
- Safety Standards: UL, CSA
RJS Systems International, 10430 Pioneer Blvd. Unit 1, Santa Fe Springs, CA 90670. Tel: 562-944-0930; Fax: 562-944-0630.