Product/Service

ILHX: In Line Heat Exchanger

Source: Lufran Inc.
One Pass, Acid or Process Fluid Heat Exchanger or Pre-Diffusion & Photo Resist Cleaning Process Reduce Waste Stream Cost
One Pass, Acid or Process Fluid Heat Exchanger or Pre-Diffusion & Photo Resist Cleaning Process Reduce Waste Stream Cost. Increase bench Throughput. 130°C Drop Throughput.

Benefits

Significantly cut acid disposal cost by reducing sfandard 10:1 water aspiration.
Reduce acid cool down time to 10-minutes. Opens bench for service sooner.
Produces 55°C Piping Safe waste with No pumps.

Specifications

Service: One pass cooling of acid or process streams.

Configuration: Vertical.

Process

  • Inlet Temperature: Up to 130°C.
  • Inlet Pressure: Gravity feed up to 20 psi.
  • Volume: 7 gal.
  • Process Time: 10-minutes.
  • Outlet Temperature: 55°C. :

Cooling Water Inlet

  • Temperature: 15°C.
  • Pressure: 50 psi.
  • .Flow: 6.0 GPM

Material:TEFLON & PVDF

Available Connection: Process and cooling lines 3/4-inch Flaretek(r) Fittings.

Mounting: Vertical with Halar coated bracket for surface or Stainless "U" bolt for panel.

Gravity Simple

The Lufran ILHX chamber reduces the hours needed to cool hot acid or other process chemistry to a mere 10 minutes which improves your bench through put. Without adding volumes of aspirating water you don't add to disposal costs.

Common connections mate the Lufran ILHX to a wide variety of systems with operating temperatures up to 130°C.

Lufran Inc., 10200 Wellman Road, Streetsboro, OH 44241. Tel: 330-655-9797; Fax: 330-656-3500.